Skip navigation
Project Details
  • Solomon
    No
    Surface
    Passive Treatment System
    Howard N.w.
    2000
    $161,373.00
    $0.00
Water Quality Data Summary
Sample PointFlow - Field!!(gal/min)pH - Field!!(S.U.)pH - Lab!!(S.U.)ORP - Field!!(mvolts)DO - Field!!(mg/L)Temp - Field!!(C)Cond - Lab!!(umhos/cm)Alkalinity - Field!!(mg/L)Alkalinity - Lab!!(mg/L)Acidity - Lab!!(mg/L)T. Fe  - Lab!!(mg/L)D. Fe - Lab!!(mg/L)T. Mn  - Lab!!(mg/L)D. Mn  - Lab!!(mg/L)T. Al - Lab!!(mg/L)D. Al - Lab!!(mg/L)SO4 - Lab!!(mg/L)TSS - Lab!!(mg/L)
PA97A9.33.723.87--4.8910.54350043.330.14--4.46--3.11--191.30
PA97C126.56.95--5.1714359106.6798.67-72.670.5--1.1--0.09--86.74.3
Treatment Technologies
Treatment Technology Quantity of Elements
Settling Pond 1
Vertical Flow Pond (VFP) 1