Skip navigation
Project Details
  • BC16
    No
    Oil/Gas Well
    Passive Treatment System
    Barkeyville
    tributary 15, Blacks Creek

    A passive system was constructed to address the BC16 discharge emanting from what appears to be a compromised oil well.

    2008
    $216,740.00
    $0.00
    1300
Water Quality Data Summary
Sample PointFlow - Field!!(gal/min)pH - Field!!(S.U.)pH - Lab!!(S.U.)ORP - Field!!(mvolts)DO - Field!!(mg/L)Temp - Field!!(C)Cond - Lab!!(umhos/cm)Alkalinity - Field!!(mg/L)Alkalinity - Lab!!(mg/L)Acidity - Lab!!(mg/L)T. Fe  - Lab!!(mg/L)D. Fe - Lab!!(mg/L)T. Mn  - Lab!!(mg/L)D. Mn  - Lab!!(mg/L)T. Al - Lab!!(mg/L)D. Al - Lab!!(mg/L)SO4 - Lab!!(mg/L)TSS - Lab!!(mg/L)
BC16A32.56.596.3270.1223.91085128.44108.03-34.7236.51--7.91--0.05--40216.3
903HFLB3114.127.15159.25.8424104765.6188.74-74.220.3101.320.960.070364.93.2
Treatment Technologies
Treatment Technology Quantity of Elements
Aerobic Wetland 1
Horizontal Flow Limestone Bed (HFLB) 1